Automated evaluation of ECG parameters during the COVID-19 pandemic
Annotation
Algorithms for prompt automated evaluation of electrocardiogram parameters in the absence of specialized equipment and specialized specialists are considered. The patient’s electrocardiogram is recorded on a paper tape, then it is photographed on the primary care doctor’s mobile phone and processed by a specialized application. The application digitizes the photographed image of the electrocardiogram, evaluates its main parameters as well as calculates criteria for the differential diagnosis of certain diseases using approximate formulas. In addition, the digitized electrocardiogram image is transmitted to the server and processed using a machine learning system. Algorithms for digitizing and analyzing an electrocardiogram have been developed that make it possible to evaluate its elements that are important for diagnosis, and the average error in determining the position of the most complex (smoothed) peaks — P and T waves — was no more than 0.1 mm. An algorithm for the criteria analysis of an electrocardiogram is proposed to support the differential diagnosis of acute myocardial infarction with ST segment elevation and early ventricular repolarization syndrome which provides accuracy values of 0.85 and F-scores of 0.74. An alternative algorithm based on a deep neural network is proposed which provides the best values — 0.96 and 0.88, respectively, but requires large computing resources and is executed on the server. The algorithms are implemented as a set of library functions. They can be used both independently and as part of a full-scale clinical decision support system for automated evaluation of electrocardiogram parameters based on a client-server architecture. In addition, all calculation results, together with a photograph of the original electrocardiogram, can be promptly transferred to a qualified cardiologist in order to receive an advisory opinion remotely.
Keywords
Постоянный URL
Articles in current issue
- Pulse recording of dynamic holograms in bismuth silicate crystal in a broad wavelength range
- Hybrid endoscope with television and multispectral image processing for the internal organs cancer early diagnostics
- Modelling of a composite waveguide holographic display
- Application of infrared spectroscopy methods in studying compositions for paper sizing
- Distribution optimization method of pixel density by surveillance area
- Evaluation and development of a method for compensating the positioning error of computer numeric control equipment
- Compensation of output external disturbances for a class of linear systems with control delay
- Luminescence technique for studying the growth of AgInS2 quantum dots
- Peculiarities of pulsed laser deposition of thin InGaAsN films in an active background gas atmosphere
- Determination of the electron distribution in thin barrier AlGaAs/GaAs superlattices by capacitance-voltage profiling
- Spectral and kinetic properties of silver sulfide quantum dots in an external electric field
- Influence of nano-sized horizontal inhomogeneities on surface profiling by means of XPS
- Organic light-emitting diodes with new dyes based on coumarin
- Fabrication and characterization of hybrid composite of Al6082/SiC/rice husk powder using friction stir processing
- A multi-path secure routing for the detection of node capturing attack in wireless sensor network
- A method for documenting architectural solutions of computing platforms
- Improving out of vocabulary words recognition accuracy for an end-to-end Russian speech recognition system
- Method for monitoring the state of elements of cyber-physical systems based on time series analysis
- Application of the text wave model to the sentiment analysis problem
- Multi-agent adaptive routing by multi-headattention-based twin agents using reinforcement learning
- Joint learning of agents and graph embeddings in a conveyor belt control problem
- Simulation of radiative transfer in gas-liquid foams
- The effect of signal-to-noise ratio value on the error in measuring acoustic emission parameters: statistical assessment
- Simulating the process of steady-state thermoreflectance for measuring the thermal conductivity of materials
- Modeling and simulation ofone- and two-row six-bladed ducted fans
- Differential-difference model of heat transfer in solids using the method of parametric identification